2CY gear pump layout and requirements

2CY gear pump for conveying solid particles and fibers, non-corrosive, the temperature is not higher than 80 ℃, the viscosity of 5 × 10-6 ~ 1.5 × 10-3m2 / s (5-1500cSt) of lubricating oil or similar nature Other liquids for lubricating oil. 1.2CY gear pump layout requirements (1) 2CY gear pump arranged in the room, generally do not consider the requirements of maneuvering vehicles access. For indoor arrangements, the pump should be placed in separate rooms with other pumps, separated by a firewall, when the temperature of the liquid being transported is higher than the natural point or if the liquid being transported is liquid hydrocarbons. Various centrifugal pump maintenance space required for inspection. Pipe layout, the pump on both sides of at least aside for maintenance purposes. Vertical 2CY gear pump arranged below the pipe gallery or frame, the top of the pump body should be set aside for installation and maintenance space required. 2CY gear pump pump or pump side and the distance between the wall should not be less than 1.2 ~ 1.5m, two rows of clear distance between the pump should not be less than 2m. Steam reciprocating pump power and pump side should be left with the piston and the pull rod position. (2) For open-air or semi-open-air pumps, the pump and the prime mover are generally perpendicular to the axis and the gallery axis. 2.2CY gear pump layout (1) open-air layout The pump is generally arranged in the gallery below or on the side, you can also arrange hybrid suction near the device, the main advantage of good ventilation, easy operation and maintenance. If the pump is arranged below the pipe gallery, the pump outlet center line should be aligned, 0.6m away from the center of the pipe gallery column. (2) Interior layout The indoor layout of the pump is suitable for cold or sandy areas, as well as the process has special requirements of the occasion. (3) Semi-outdoor layout Semi-outdoor arrangement 2CY gear pump is suitable for rainy areas, according to the pump layout requirements, the pump arranged in a single row, double row or multiple rows. Pumps are usually arranged below the pipe gallery, the ceiling in the upper part of the pipeline. Or the pump layout in the framework of the ground floor to the framework of the platform as a roof.

High Bay Lamp

High Bay Lamp,High Bay Led Light Fixtures,Finished Street Lights,Street Light With Led

Changzhou Jingui Lighting Technology Co., Ltd , https://www.jinguilighting.com

This entry was posted in on