2.1 Mathematical description of the cutting surface of the tool
The cutting surface of the tool is described in the form of a homogeneous function matrix [2] . In Figure 1, O P is the cutting plane coordinate system, O C is the coordinate system of the cutting surface point, and the X C coordinate points to the physical material direction of the tool, r Is the radius of gyration of the tool. This allows the cutting surface of the tool to be described in the O P coordinate system as follows:
(1)
Where C γ P =cos(γ P ), S γ P =sin(γ P ), {x C } C is the coordinate array of points in the O C coordinate system, and {x C } P is in the O P coordinate system The coordinate array of points, [T PC ] is the description matrix of the cutting face of the tool.
2.2 Mathematical description of the machined surface
It is still described in the form of a homogeneous function matrix. As shown in Fig. 2, O W is the workpiece coordinate system, O S is the coordinate system at a point on the machined surface, the X S coordinate points to the outer normal of the machined surface, and the Y S coordinate is the tangential direction of the bus bar of the machined surface. This way you can find a description of the machined surface in the O W coordinate system:
(2)
Where [ W T S ] - the description matrix of the machined surface
Figure 2 workpiece machining surface description coordinate system
Previous page next page
This product is used in collecting high-quality DNA/RNA samples from saliva and can be used in various biological experiments such as enzymatic hydrolysis, PCR, and next-generation sequencing. It is widely used for the collection and preservation of specimens in hospitals, scientific research institutions, and families. The collection process is easy and painless, and will not cause any damage or discomfort to the human body.
Features
♦ Contactless sample collection, less risk for healthcare workers.
♦ Suitable for all kinds of people, easy method to collect samples.
♦ Easy to use, non-invasive collection.
♦ Use medical PP material.
The Saliva Collection Kit is a complete kit made out of 100% polypropylene.
The funnel has been engineered to be intuitively easy to use and specifically designed to reduce user self-collection error by preventing flowback.
When saliva is captured in a sterile container, COVID-19 is stable at room temperature for up to seven days without the need for expensive reagents.
Saliva Collection,Saliva Collector,Spit Collector,Saliva Collection Device,Saliva Sample Collector
Yong Yue Medical Technology(Kunshan) Co.,Ltd , https://www.yongyuepcr.com