I. Fire Safety Organization Structure Figure 1: Fire Safety Organization Structure Figure 2: Fire Safety Manager 3: Fire Protection Equipment Manager 4: Fire Manager (Project Leader) Communication Group 1: (Guard Team) Equipment Group 3: (Engineering Department) Cleaning Team 3; (Customer Service) Ambulance Team 4; (Guard) Evacuation Team
Second, the fire control room duty duty, management system 1, strictly abide by the shift system, and carefully fill in the transfer record, the transfer is not clear by the successor. 2. On-duty shifts are to be transferred 10 minutes in advance, and the successors who are not on duty are not allowed to leave work. The shift must be approved by the supervisor. 3. It is forbidden to sleep, drink, read newspapers, chat, make private calls, and visit guests in the control room while on duty. It is forbidden for non-supervisory room watchers to touch and use indoor equipment. 4. To monitor the operation status of the equipment closely, to handle the alarm promptly and accurately according to the prescribed procedures, to make a variety of records, and to report to the leader in case of an important situation. 5. The automatic fire alarm system and automatic fire extinguishing system cannot be closed or disabled without the consent of the relevant authorities. 6, the control room is strictly prohibited smoking and stacking irrelevant items. 7. Workers in non-monitoring rooms must not enter the surveillance room and must register due to work reasons. 8, to ensure the smooth flow of the telephone line alarm, not to talk about things unrelated to the work. 9. Responsible for the monitoring and operation of all kinds of fire control equipment, do a good job of inspection and other work, and must not leave the post. 10. Be familiar with the basic principles and functions of the fire-fighting facility system used in this system, master the operating technology, assist the technicians in repairing and maintaining, and do not disassemble, misappropriate or disable them without authorization to ensure the normal operation of the equipment. 11. It is not allowed to change, change, delete, or increase the procedures of control equipment without authorization. Any change must be approved by the supervisor. 12. Fire alarms should be confirmed as soon as possible, timely and accurately start relevant firefighting equipment, properly and effectively organize fire fighting and personnel evacuation, give good advice to the leadership, and report to the 119 public security fire brigade according to the fire situation. After the fire brigade arrives, assist the firefighters. Extinguish the fire, protect the fire scene, and assist in investigating the cause of the fire. 13. Conduct frequent inspections of fire control room equipment and communication equipment, and regularly perform various system tests to ensure that the fire fighting facilities operate in good condition. Do a good job in handover work and carefully fill in duty records. 14. Propaganda and implementation of fire safety regulations, consciously abide by the fire safety management system, and complete all kinds of technical work and daily management work with a high sense of responsibility. 15. If there is indeed a fire, it shall be immediately reported to the surveillance room and, with its own safety, be extinguished by the use of on-site fire-fighting facilities and extinguishing equipment. 16. After the control room receives the alarm, fire the relevant fire equipment according to the fire situation, notify the relevant personnel to the scene to extinguish the fire, report to the superior leadership, and call the “119†alarm as needed. When dialing 119, it should be accurately reported: "The address of the residential area is ********************************************************************************************************************************************************************************************************************* , At the same time send someone to the nearby important intersection to guide the fire engine to quickly and accurately reach the fire scene. "17. After the fire treatment is completed, restore the normal operation of the fire equipment, and make records." 18. On-duty personnel should dress neatly, stick to their positions, and be strictly prohibited from taking off. 19. On-duty personnel should earnestly study fire laws, regulations, learn fire-fighting expertise, be proficient in the performance and operation procedures of fire-fighting equipment, and continuously improve their business level. 20. Actively participate in fire safety professional and technical training and improve professional quality. 21, receive the alarm signal should be promptly confirmed, and immediately send personnel to carry the radio and other communications tools, quickly arrived at the alarm point to view. 22. If no fire has occurred, the cause of the alarm should be ascertained. Take relevant measures and carefully record the situation. Report the situation to the monitoring room.
Third, the fire emergency plan 1: receive the alarm 2: determine the location of the alarm, immediately sent to the incident site to confirm the minor fire: the property orderers themselves to deal with serious fire: dial 119 fire call to inform the fire chief, project manager mistake Newspaper: Find out the cause and record it. Inform Weibao Fangwei that the fire is serious. See the following preplans for evacuation of personnel and carry out security protection. The team members rushed to the site to extinguish the fire and clear the fire exit, guide the fire truck to cut off the gas, and the mains converted to emergency power. The inspection has started automatically. The firefighting equipment work conditions, the necessary mandatory start-up of relevant fire-fighting equipment to detect fire conditions, sticking to the control center position to assist the fire control authority in handling the fire scene, doing a good job in the disaster record, assisting the investigation, and reporting to the relevant competent authorities.
Fourth, the host computer specific operating rules: 1, fire alarm processing: (1) real fire alarm: the host receives the alarm message, the on-duty personnel to the scene to confirm the fire, confirm the real fire alarm message, immediately start the "fire emergency plan." (2) False positive report processing: The host computer receives the warning message, the on-the-spot personnel arrives at the scene to carry on the fire alarm message confirmation, after confirming for the false report, carries on the silencing, resets the operation and records, the operation is completed. After multiple alarms occur on the same device, notify the fire protection and maintenance unit for maintenance. 2. Automatic conversion of fire main engine: Click the “User settings†button. When “Please enter password†screen appears, click “confirm†button. There are 8 options on the screen interface. Click the number key “3†to select the third item “3 start. "Settings", enter the "startup mode setting" interface, there are four options on the interface, select "1 manual start control" or "2 automatic start control" start mode, click the corresponding number key "1" or "2" to select the start mode. If you enter the manual start, click the number "1" key to enter the manual setting interface "1 manual inhibition" and "2 manual permission". Select the number key "1" or "2" as needed, and click "OK" to complete the setting. Click "Cancel" button to return to the main interface. 3, start the manual disk device: When the host is under the manual state, when you need to start the relevant equipment, directly click the manual disk related device button. Example: It is necessary to start the 17th floor broadcast of the 2nd unit of Building No. 4, and directly click on the button labeled “Building No. 4 Building No. 2 Unit 17 Floor†on the manual disk. To cancel the startup click this button again. 4. Manually start the pump and blower system: In the manual state, the host will adjust the start key to “Allow†state, directly click the red button on the left side of the selected device, and click the red button on the right side when it needs to stop. (The condition is that the control cabinet of the peripheral related equipment is in the automatic state) Example: To start the spray No. 1 pump, click the red button on the left side of the “spray pump No. 1 pump†option, and click the red button on the right side when it is stopped. 5. Fire broadcast broadcasting: Each broadcast power amplifier is under working condition, and select the relevant button that needs to start broadcasting (For the details of the control panel options, see “Article 6 and Operation 2â€). Broadcast music or handheld microphone for voice Broadcast 6. Call between the fire main unit and the extension: Bring up the fire intercom phone microphone, enter the password “4 1â€, click on the selected call area to achieve the call.
Fifth, the fire control room management system 1, the fire control room must be implemented on a 24-hour day dedicated personnel system, each class is not less than 2 people. 2. The daily management of the fire control room shall comply with the relevant requirements of the “Maintenance Management of Building Fire Protection Facilities†[GA587]. 3. The fire control room shall ensure that the fire automatic alarm system and the fire extinguishing system are in normal working condition. 4. The fire control room shall ensure that the high-level fire water storage tanks, fire water tanks, pressure water tanks and other fire water storage facilities have enough water; ensure that the fire pump outlet pipe network valves, automatic sprinkler system pipe network valves are in the normally open state; ensure that the fire pump, The switch cabinets of fire-fighting electrical equipment such as smoke exhaust fans and fire shutters are in the automatic (on) position. 6. Fire Controller Operation Procedure 1. Basic Contents: 1.1 The operator must be very familiar with the working principle of the fire control room. 1.2 The control screen is in normal standby. The panel has a DC voltage output display, and the power supply voltage indication and backup power indicator light are on. 1.3 Each indicator light on the control panel corresponds to an information indication. 1.4 When a fire alarm message occurs in a certain range, the control panel will give an audible alarm at the first time. At the same time, the alarm indicator on the panel will light up. The duty officer immediately confirmed the authenticity of the fire alarm and started the relevant plan. 1.5 Routine Inspection and Maintenance 1.5.1 Each day, the lights and tables on the control panel are inspected. 1.5.2 Perform test work on the indicators on the screen each week and find that the damage is immediately replaced. 2. Adjust the automatic and manual buttons to the automatic position and wait for the alarm. 3. Purpose: To ensure the normal operation of the district fire-fighting system. 4. Scope of application: Fire protection system within the community 5. Job responsibilities: 5.1 The orderly maintenance team leader is responsible for the supervision and inspection. 5.2 The patrolman is responsible for the operation and daily inspection. 6. The maintenance department technician is responsible for the maintenance of the control cabinet.
Wrought Iron Doors,Iron Doors,Safety Wrought Iron Door,Steel Doors
Ming Yi iron arts company , https://www.mingyi-ironware.com