Emergency treatment method for styrene leakage accident

News Related Keywords: No tags.

1, leakage emergency treatment and disposal

(1) Immediately notify the relevant government departments and emergency headquarters.
(2) Remove the ignition source and isolate the general staff.
(3) Prevent leakage as much as possible with a safety license.

Small leaks: absorbed with activated carbon or other inert materials, can also be used

Otherwise, the emulsion made from the dispersant will be scrubbed, and the lotion will be sealed and transported to the recyclable unit after being diluted and kept away from the reservoir to ensure the water quality of the reservoir.

A lot of leakage: Covering the embankment or digging holes for shelter and covering with foam to reduce steam disasters. Transfer to an emergency collection tank with a pump and recover the cargo for disposal at the waste treatment plant.

2, protective measures

It is recommended that emergency personnel wear self-contained positive pressure breathing apparatus and wear protective fire protection clothing .

3, fire extinguishing methods

As far as possible, transfer the container from the fire to the open space, but be sure to keep away from the water in the Xinlicheng Reservoir and cool it with a condensate until the end of the fire. Extinguishing agents: foam, dry powder, carbon dioxide, sand. Important note: Restricting the use of water to extinguish the fire will cause water pollution in the reservoir.

ISO Standard Mass Flow Meter

Zhejiang Sealand Technology Co., Ltd. is a trustworthy manufacturer of Mass Flow Meter Coriolis, Flow Meter Coriolis, Mass Flowmeter Coriolis, Mass Meter Coriolis, Meter Coriolis, Flowmeter Coriolis, ISO/ IEC 17025 standard.

Sealand meter is certified by Zhejiang Institute of Metrology. To get such certificate, Sealand has to send all models to Zhejiang Institute of Metrology and all models are tested in their calibration lab. The lab is an ISO/IEC 17025:2005 standard lab approved by CNAS (China National Accreditation Service for Conformity Assessment). CNAS is a member of ILAC (International Laboratory Accreditation Cooperation).


Besides, Sealand has its own calibration lab, equipped with METTLER TOLEDO scales with accuracy 0.014% and the device extended uncertainty is 0.05%. The lab is also approved by Zhejiang Institute of Metrology. This certificate will stay valid only for one year, Zhejiang Institute of Metrology will send their professor to Sealand every year to check and make sure that the lab is qualified still and then issue new certificate. During the production, each meter will be calibrated in this lab for 3 times, each time at 5 different flow rate.

Mass Flow Meter Coriolis, Flow Meter Coriolis, Mass Flowmeter Coriolis, Mass Meter Coriolis, Meter Coriolis, Flowmeter Coriolis

Zhejiang Sealand Technology Co., Ltd. , https://www.sealandflowmeters.com

This entry was posted in on